Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" June 11, 1992 Utility File Layout - ASCII Format Years: 1987 thru Present ----------------------------------------------------------------------------------------- ! ! ! ! ! ! ! ! ! Field ! Field Name ! Columns ! No. of ! . ! .. ! Special ! ! No. ! ! From To ! Columns ! ! ! Instructions ! ! ! ! ! ! ! ! ! !-------!----------------------!-------------!---------!-----!------!-------------------! ! ! ! ! ! ! ! ! ! ! 1 ! Utility Code ! 0001 ! 0005 ! 005 ! N ! ! ! ! 2 ! Utility Name ! 0006 ! 0035 ! 030 ! A ! ! ! ! 3 ! Address Line 1 ! 0036 ! 0065 ! 030 ! A ! ! ! ! 4 ! Address Line 2 ! 0066 ! 0095 ! 030 ! A ! ! ! ! 5 ! Address Line 3 ! 0096 ! 0125 ! 030 ! A ! ! ! ! 6 ! Address Line 4 ! 0126 ! 0155 ! 030 ! A ! ! ! ! 7 ! Address Line 5 ! 0156 ! 0185 ! 030 ! A ! ! ! ! 8 ! City ! 0186 ! 0205 ! 020 ! A ! ! ! ! 9 ! State ! 0206 ! 0207 ! 002 ! A ! ! ! ! 10 ! Zip Code ! 0208 ! 0212 ! 005 ! N ! ! ! ! 11 ! Expanded Zip Code ! 0213 ! 0216 ! 004 ! N ! ! ! ! 12 ! Contact Name ! 0217 ! 0236 ! 020 ! A ! ! ! ! 13 ! Contact Title ! 0237 ! 0256 ! 020 ! A ! ! ! ! 14 ! Area Code ! 0257 ! 0259 ! 003 ! A ! ! ! ! 15 ! Exchange ! 0260 ! 0262 ! 003 ! N ! ! ! ! 16 ! Phone Number ! 0263 ! 0266 ! 004 ! N ! ! ! ! 17 ! Extension ! 0267 ! 0270 ! 004 ! A ! ! ! ! 18 ! Certify Name ! 0271 ! 0290 ! 020 ! A ! ! ! ! 19 ! Certify Title ! 0291 ! 0310 ! 020 ! A ! ! ! ! 20 ! Certify Date ! 0311 ! 0316 ! 006 ! N ! ! ! ! 21 ! NERC - ASCC ! 0317 ! 0317 ! 001 ! A ! ! Note 1 ! ! 22 ! NERC - ECAR ! 0318 ! 0318 ! 001 ! A ! ! Note 1 ! ! 23 ! NERC - ERCOT ! 0319 ! 0319 ! 001 ! A ! ! Note 1 ! ! 24 ! NERC - MAIN ! 0320 ! 0320 ! 001 ! A ! ! Note 1 ! ! 25 ! NERC - MAAC ! 0321 ! 0321 ! 001 ! A ! ! Note 1 ! ! 26 ! NERC - MAPP ! 0322 ! 0322 ! 001 ! A ! ! Note 1 ! ! 27 ! NERC - NPCC ! 0323 ! 0323 ! 001 ! A ! ! Note 1 ! ! 28 ! NERC - SERC ! 0324 ! 0324 ! 001 ! A ! ! Note 1 ! ! 29 ! NERC - SPP ! 0325 ! 0325 ! 001 ! A ! ! Note 1 ! ! 30 ! NERC - WSCC ! 0326 ! 0326 ! 001 ! A ! ! Note 1 ! ! 31 ! NERC - HI ! 0327 ! 0327 ! 001 ! A ! ! Note 1 ! ! 32 ! NERC - PR/Terr ! 0328 ! 0328 ! 001 ! A ! ! Note 1 ! ! ! ! ! ! ! ! ! ! ----------------------------------------------------------------------------------------- . A - Alpha/Numeric .. LB - Left Justify, Blank Filled N - Numeric LZ - Left Justify, Zero Filled D - Duplicate RB - Right Justify, Blank Filled S - Skip RZ - Right Justify, Zero Filled Unless otherwise noted all alpha/numeric fields are left justified, blank filled. All numeric fields are right justified, zero filled. Numeric fields in this layout do not contain negative values or decimal points. Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Utility file Information Field Explanation No.(s) ------ ----------- 3-11 Form EIA-860 respondent mailing address 12-17 Form EIA-860 contact person's name, title, telephone number 18-20 Form EIA-860 certifying official's name, title, and date of certification Note 1: North American Electric Reliability Council (NERC) regions, NERC affiliate region, and/or areas in which the utility operates. An 'X' in this field indicates association. The NERC regional councils are: ECAR - East Central Area Reliability Coordination Agreement ERCOT - Electric Reliability Council of Texas MAAC - Mid-Atlantic Area Council MAIN - Mid-American Interpool Network MAPP - Mid-Continent Area Power Pool NPCC - Northeast Power Coordinating Council SERC - Southeastern Electric Reliability Council SPP - Southwest Power Pool WSCC - Western Systems Coordinating Council The NERC affiliate regional council is: ASCC - Alaska Systems Coordinating Council The areas are: HI - Hawaii PR/Terr - Puerto Rico/U.S. Territories 1 Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Plant File Layout - ASCII Format ----------------------------------------------------------------------------------------- ! ! ! ! ! ! ! ! ! Field ! Field Name ! Columns ! No. of ! . ! .. ! Special ! ! No. ! ! From To ! Columns ! ! ! Instructions ! ! ! ! ! ! ! ! ! !-------!----------------------!-------------!---------!-----!------!-------------------! ! ! ! ! ! ! ! ! ! ! 1 ! Utility Code ! 0001 ! 0005 ! 005 ! N ! ! ! ! 2 ! Plant Code ! 0006 ! 0009 ! 004 ! N ! ! ! ! 3 ! Plant Name ! 0010 ! 0029 ! 020 ! A ! ! ! ! 4 ! County Code ! 0030 ! 0032 ! 003 ! N ! ! ! ! 5 ! County Name ! 0033 ! 0052 ! 020 ! A ! ! ! ! 6 ! Plant State ! 0053 ! 0054 ! 002 ! A ! ! ! ! 7 ! Plant Zip Code ! 0055 ! 0063 ! 009 ! N ! ! ! ! 8 ! Elevation ! 0064 ! 0068 ! 005 ! N ! ! In Feet ! ! 9 ! Water Source ! 0069 ! 0102 ! 034 ! A ! ! ! ! 10 ! Nonutility Use ! 0103 ! 0103 ! 001 ! A ! ! ! ! 11 ! Cooling Code 1 ! 0104 ! 0105 ! 002 ! A ! ! ! ! 12 ! Cooling Code 2 ! 0106 ! 0107 ! 002 ! A ! ! ! ! 13 ! Cooling Code 3 ! 0108 ! 0109 ! 002 ! A ! ! ! ! 14 ! Hydro. Project No. ! 0110 ! 0114 ! 005 ! N ! ! ! ! 15 ! Hydro. Project Name ! 0113 ! 0148 ! 034 ! A ! ! ! ! 16 ! Upper Pool Area ! 0149 ! 0155 ! 007 ! N ! ! In Acres ! ! 17 ! Lower Pool Area ! 0156 ! 0162 ! 007 ! N ! ! In Acres ! ! 18 ! Drainage Area ! 0163 ! 0169 ! 007 ! N ! ! In Sq. Miles ! ! 19 ! Drawdown ! 0170 ! 0173 ! 004 ! N ! ! In Feet ! ! 20 ! Usable Storage ! 0174 ! 0182 ! 009 ! N ! ! In Acre Feet ! ! 21 ! Pool Elevation ! 0183 ! 0187 ! 005 ! N ! ! In Feet ! ! 22 ! Gross Head ! 0188 ! 0191 ! 004 ! N ! ! In Feet ! ! 23 ! Design Head ! 0192 ! 0195 ! 004 ! N ! ! In Feet ! ! 24 ! Kind of Plant ! 0194 ! 0197 ! 002 ! A ! ! ! ! 25 ! Mobile Plant ! 0198 ! 0198 ! 001 ! A ! ! 'Y' if Mobile ! ! 26 ! Plant NERC ! 0199 ! 0203 ! 005 ! A ! ! ! ! 27 ! Notes Flag ! 0204 ! 0204 ! 001 ! A ! ! ! ! 28 ! Notes ! 0205 ! 0324 ! 120 ! A ! ! ! ! ! ! ! ! ! ! ! ! ----------------------------------------------------------------------------------------- . A - Alpha/Numeric .. LB - Left Justify, Blank Filled N - Numeric LZ - Left Justify, Zero Filled D - Duplicate RB - Right Justify, Blank Filled S - Skip RZ - Right Justify, Zero Filled Unless otherwise noted all alpha/numeric fields are left justified, blank filled. All numeric fields are right justified, zero filled. Numeric fields in this layout do not contain negative values or decimal points. 1 Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Plant File Information, Meaning of Codes Field Field Name Codes No.(s) ------ ---------- ----- 10 Nonutility Use S - Steam H - Hot Water B - Both N - None U - Unknown 11,12,13 Cooling Codes NO - None (No boilers or reactors) OC - Once Through with Cooling Pond(s) or Canal(s) OF - Once Through, Fresh Water OS - Once Through, Saline Water RC - Recirculating with Cooling Pond(s) or Canal(s) RF - Recirculating with Forced Draft Cooling Tower(s) RN - Recirculating with Natural Draft Cooling Tower(s) OT - Other NA - Not Applicable 24 Kind of Plant PP - Pipeline PS - Pumped Storage RR - Run-of-River ST - Storage 1 Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Generator File Layout, Record Type 3 - ASCII Format ----------------------------------------------------------------------------------------- ! ! ! ! ! ! ! ! ! Field ! Field Name ! Columns ! No. of ! . ! .. ! Special ! ! No. ! ! From To ! Columns ! ! ! Instructions ! ! ! ! ! ! ! ! ! !-------!----------------------!-------------!---------!-----!------!-------------------! ! ! ! ! ! ! ! ! ! ! 1 ! Generator Record Type! 0001 ! 0001 ! 001 ! N ! ! Note 1 ! ! 2 ! Multi-Generator Unit ! 0002 ! 0005 ! 004 ! A ! ! Note 2 ! ! 3 ! Utility Code ! 0006 ! 0010 ! 005 ! N ! ! ! ! 4 ! Plant Code ! 0011 ! 0014 ! 004 ! N ! ! ! ! 5 ! Generator Code ! 0015 ! 0018 ! 004 ! A ! ! ! ! 6 ! Prime Mover ! 0019 ! 0020 ! 002 ! A ! ! ! ! 7 ! Nameplate Capacity ! 0021 ! 0027 ! 007 ! N ! ! Note 3 In kW ! ! 8 ! Service Type ! 0028 ! 0028 ! 001 ! A ! ! Note 3 ! ! 9 ! Status Code ! 0029 ! 0030 ! 002 ! A ! ! Note 3 ! ! 10 ! In-service Month ! 0031 ! 0032 ! 002 ! N ! ! Note 3 ! ! 11 ! In-service Year ! 0033 ! 0036 ! 004 ! N ! ! Note 3 ! ! 12 ! Start-up Fuel 1 ! 0037 ! 0039 ! 003 ! A ! ! Note 3 ! ! 13 ! Start-up Fuel 2 ! 0040 ! 0042 ! 003 ! A ! ! Note 3 ! ! 14 ! Start-up Fuel 3 ! 0043 ! 0045 ! 003 ! A ! ! Note 3 ! ! 15 ! Energy Source 1 ! 0046 ! 0048 ! 003 ! A ! ! Note 3 ! ! 16 ! Energy Source 2 ! 0049 ! 0051 ! 003 ! A ! ! Note 3 ! ! 17 ! Energy Source 3 ! 0052 ! 0054 ! 003 ! A ! ! Note 3 ! ! 18 ! Heat Rate ! 0055 ! 0059 ! 005 ! N ! ! Note 3 Btu/kWh ! ! 19 ! Summer Capability ! 0060 ! 0066 ! 007 ! N ! ! Note 3 In kW ! ! 20 ! Winter Capability ! 0067 ! 0073 ! 007 ! N ! ! Note 3 In kW ! ! 21 ! Nameplate Capacity ! 0074 ! 0080 ! 007 ! N ! ! Note 4 In kW ! ! 22 ! Status Code ! 0081 ! 0082 ! 002 ! A ! ! Note 4 ! ! 23 ! Retire/Cancel Month ! 0083 ! 0084 ! 002 ! N ! ! Note 4 ! ! 24 ! Retire/Cancel Year ! 0085 ! 0088 ! 004 ! N ! ! Note 4 ! ! 25 ! Original In-ser. Mn. ! 0089 ! 0090 ! 002 ! N ! ! Note 4 ! ! 26 ! Original In-ser. Yr. ! 0091 ! 0094 ! 004 ! N ! ! Note 4 ! ! 27 ! Current In-ser. Mn. ! 0095 ! 0096 ! 002 ! N ! ! Note 4 ! ! 28 ! Current In-ser. Yr. ! 0097 ! 0100 ! 004 ! N ! ! Note 4 ! ! 29 ! Cancl/Delay Reason 1 ! 0101 ! 0102 ! 002 ! A ! ! Note 4 ! ! 30 ! Cancl/Delay Reason 2 ! 0103 ! 0104 ! 002 ! A ! ! Note 4 ! ! 31 ! Cancl/Delay Reason 3 ! 0105 ! 0106 ! 002 ! A ! ! Note 4 ! ! 32 ! Energy Source 1 ! 0107 ! 0109 ! 003 ! A ! ! Note 4 ! ! 33 ! Energy Source 2 ! 0110 ! 0112 ! 003 ! A ! ! Note 4 ! ! 34 ! Energy Source 3 ! 0113 ! 0115 ! 003 ! A ! ! Note 4 ! ! 35 ! Summer Capability ! 0116 ! 0122 ! 007 ! N ! ! Note 4 In kW ! ! 36 ! Winter Capability ! 0123 ! 0129 ! 007 ! N ! ! Note 4 In kW ! ! 37 ! Design Elect. Rating ! 0130 ! 0136 ! 007 ! N ! ! Note 5 In kW ! ! 38 ! Start Operation Month! 0137 ! 0138 ! 002 ! N ! ! Note 3 ! ! 39 ! Start Operation Year ! 0139 ! 0142 ! 004 ! N ! ! Note 3 ! ! 40 ! Est Summer Capability! 0143 ! 0149 ! 007 ! N ! ! Note 4 In kW ! ! 41 ! Est Winter Capability! 0150 ! 0156 ! 007 ! N ! ! Note 4 In kW ! ! 42 ! First Elect. Flag ! 0157 ! 0157 ! 001 ! A ! ! Note 3 ! ! 43 !Summer Capability Flag! 0158 ! 0158 ! 001 ! A ! ! Note 3 ! ! 44 !Winter Capability Flag! 0159 ! 0159 ! 001 ! A ! ! Note 3 ! ! 45 ! New Mover ! 0160 ! 0161 ! 002 ! A ! ! ! ! 46 ! Notes Flag ! 0162 ! 0162 ! 001 ! A ! ! ! ! 47 ! Notes ! 0163 ! 0282 ! 120 ! A ! ! ! ! 48 ! EIA-759 Status ! 0283 ! 0284 ! 002 ! A ! ! ! ! 49 ! EIA-759 Nameplate ! 0285 ! 0291 ! 007 ! N ! ! ! ! ! ! ! ! ! ! ! ! ----------------------------------------------------------------------------------------- . A - Alpha/Numeric .. LB - Left Justify, Blank Filled N - Numeric LZ - Left Justify, Zero Filled D - Duplicate RB - Right Justify, Blank Filled S - Skip RZ - Right Justify, Zero Filled Unless otherwise noted all alpha/numeric fields are left justified, blank filled. All numeric fields are right justified, zero filled. Numeric fields in this layout do not contain negative values or decimal points. kW kilowatts Btu British Thermal Units kWh kilowatthours Note 1: This field must contain a '3' for this layout to apply. Note 2: This field applies to generators that operate as a unit. This identical four-character code is the identifier that links these generators. These generators have an aggregate capability and may have a single heat rate reported. Note 3: This field applies to existing (operable) generators and retired or sold generators; status code (field 9) 'OP', 'OS', 'SB', or 'TS' apply; and, status code (22) 'SD', 'RE' apply. Note 4: This field applies to generators that are proposed to start operation within 10 years; for generators that are cancelled, delayed beyond the 10-year period, indefinitely postponed; for generators that have been retired or sold to a nonutility; for existing generators that are either proposed for conversion to another energy source, or proposed for other modification within 10 years; for existing generators that are proposed for retirement; code (field 22) 'CN', 'CO', 'FC', 'IP', 'MO', 'PL', 'RT' or 'OT' apply. Note 5: Nuclear Reactors Only 1 Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Generator File Information, Record Type 3, Meaning of Codes Field Field Name Codes No.(s) ------ ---------- ----- 6 Prime Mover CA - Combined Cycle Steam Turbine with Supplementary Firing CT - Combined Cycle Combustion Turbine CS - Combined Cycle Single Shaft CW - Combined Cycle Steam Turbine Waste Heat Boiler Only FC - Fuel Cell (electrochemical) GE - Steam Turbine (geothermal) GT - Combustion (gas) Turbine HC - Hydraulic Turbine (conventional) HL - Hydraulic Turbine (pipeline) HR - Hydraulic Turbine Reversible (pumped storage) IC - Internal Combustion JE - Jet Engine NB - Steam Turbine (Boiling Water Nuclear Reactor) NG - Steam Turbine (Graphite Nuclear Reactor) NH - Steam Turbine (High-Temperature Gas-Cooled Nuclear Reactor NP - Steam Turbine (Pressurized Water Nuclear Reactor OC - Ocean Thermal Turbine SP - Photovoltaic SS - Steam Turbine (Solar) ST - Steam Turbine (Boiler) NA - Unknown at this time WT - Wind Turbine OT - Other (Explained in Notes) 8 Service Type B - Baseload C - Cycling or intermediate P - Peaking Load 9 Status Code OP - Operating (in commercial service or out of service less than 365 days) OS - Out of Service (365 days or longer) SB - Standby SD - Sold to nonutility TS - Testing, Generating Power to the Grid 10,11 In-service Month -Date of initial commercial operation In-service Year 12,13,14 Start-up Fuels ANT - Anthracite 15,16,17 Energy Sources BFG - Blast Furnace Gas 32,33,34 BIT - Bituminous Coal COG - Coke Oven Gas COL - Coal (generic) COM - Coal-Oil Mixture CRU - Crude Oil CWM - Coal-Water Mixture FO1 - No. 1 Fuel Oil FO2 - No. 2 Fuel Oil FO4 - No. 4 Fuel Oil FO5 - No. 5 Fuel Oil FO6 - No. 6 Fuel Oil GAS - Gas (generic) GST - Geothermal Steam JF - Jet Fuel KER - Kerosene LIG - Lignite LNG - Liquified Natural Gas LPG - Liquified Propane Gas MF - Multifueled MTH - Methanol NG - Natural Gas PC - Petroleum Coke PET - Petroleum (generic) PL - Plutonium REF - Refuse, Bagasse and all other nonwood waste RG - Refinery Gas RRO - Re-Refined Motor Oil SNG - Synthetic Natural Gas STM - Steam SUB - Subbituminous Coal SUN - Solar TOP - Topped Crude Oil UR - Uranium WAT - Water WD - Wood and Wood Waste WH - Waste Heat WND - Wind OT - Other (explain under notes) NA - Not Available 22 Status Code CN - Cancelled CO - New Unit Under Construction FC - Planned for Conversion to another fuel IP - Planned Generator Indefinitely Postponed LP - Low Power Testing (Nuclear Only) MO - Modification planned for an existing generator PL - Planned (proposed unit not under construction) RE - Retired RT - Scheduled for Retirement SD - Sold to nonutility OT - Other (Explained in Notes) 23,24 Retire/Cancel Month - Date generator was retired from Retire/Cancel Year service, or date generator was sold to nonutility; date existing generator proposed for retirement; date plans for construction of new generator were cancelled; date decision was made to postpone indefinitely the construction of new generator; 25,26 Original In-Ser Mn - Original date proposed Original In-Ser Yr new generator expected to start generating or original date proposed change in existing generator expected to be completed. 27,28 Current In-Ser Mn - Current date new generator Current In-Ser Yr expected to start generating electricity to the grid; for nuclear, current date that full power operating license expected to be issued for the reactor; current date proposed change in existing generator expected to be completed. 29,30,31 Cancl/Delay AP - Prolonged procedures to obtain Federal, State or Local approvals DE - Delay of associated facilities DI - Natural Disaster EF - Equipment Failure EQ - Late delivery of equipment FI - Financial Problems LA - Labor Problems LE - Environmental, site or legal challenges LO - Revised load forecast RE - Changes in regulatory requirements ST - Manufacturing, construction or transportation strikes OT - Other (Describe in Notes) 35,36 Summer Capability - Utility reported values for Winter Capability proposed generators; 38,39 Start Operation Month - Date generator first became Start Operation Year available to provide electricity to the grid; for nuclear, the date full power operating license was granted. Energy Information Administration's estimated date for issuance of full power operating license for proposed nuclear generators; 40,41 Est Summer Capability - Energy Information Administration's Est Winter Capability estimated values for proposed generators. 42 First Elect. Flag - If this field contains an 'E' then fields 38 and 39 are the Energy Information Administration's estimated values. If this field is blank, then fields 38 and 39 are utility reported values. 43 Summer Capability Flag - If this field contains an 'E', then field 19 is the Energy Information Administration's estimated value. If this field is blank, then field 19 is a utility reported value. 44 Winter Capability Flag - If this field contains an 'E', then field 20 is the Energy Information Administration's estimated value. If this field is blank, then field 20 is a utility reported value. 1 Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Generator File Layout, Record Type 4 ASCII Format ----------------------------------------------------------------------------------------- ! ! ! ! ! ! ! ! ! Field ! Field Name ! Columns ! No. of ! . ! .. ! Special ! ! No. ! ! From To ! Columns ! ! ! Instructions ! ! ! ! ! ! ! ! ! !-------!----------------------!-------------!---------!-----!------!-------------------! ! ! ! ! ! ! ! ! ! ! 1 ! Generator Recd. Type ! 0001 ! 0001 ! 001 ! N ! ! Note 1 ! ! 2 ! Utility Code ! 0002 ! 0006 ! 005 ! N ! ! ! ! 3 ! Plant Code ! 0007 ! 0010 ! 004 ! N ! ! ! ! 4 ! Generator Code ! 0011 ! 0014 ! 004 ! A ! ! ! ! 5 ! Ownership ! 0015 ! 0164 ! 150 ! N ! ! Note 2 ! ! 6 ! Notes Flag ! 0165 ! 0165 ! 001 ! A ! ! ! ! 7 ! Notes ! 0166 ! 0285 ! 120 ! A ! ! ! ! ! ! ! ! ! ! ! ! ----------------------------------------------------------------------------------------- . A - Alpha/Numeric .. LB - Left Justify, Blank Filled N - Numeric LZ - Left Justify, Zero Filled D - Duplicate RB - Right Justify, Blank Filled S - Skip RZ - Right Justify, Zero Filled Unless otherwise noted all alpha/numeric fields are left justified, blank filled. All numeric fields are right justified, zero filled. Note 1: This field must contain a '4' for this layout to apply. Note 2: The ownership field contains a one dimensional array which occurs 10 times. The logical layout of the 150 columns follows. The format is Common Business Oriented Language (COBOL). 05 OWNERSHIP OCCURS 10 TIMES. 10 OWNER-UTILITY PIC 9(10). 10 OWNER-PERCENT PIC 999V99. The two numeric fields do not contain negative values but the OWNER-PERCENT field does have an implied decimal point. 1 Form EIA-860, "ANNUAL ELECTRIC GENERATOR REPORT" Generator File Layout, Record Type 5 ASCII Format ----------------------------------------------------------------------------------------- ! ! ! ! ! ! ! ! ! Field ! Field Name ! Columns ! No. of ! . ! .. ! Special ! ! No. ! ! From To ! Columns ! ! ! Instructions ! ! ! ! ! ! ! ! ! !-------!----------------------!-------------!---------!-----!------!-------------------! ! ! ! ! ! ! ! ! ! ! 1 ! Generator Recd. Type ! 0001 ! 0001 ! 001 ! N ! ! Note 1 ! ! 2 ! Utility Code ! 0002 ! 0006 ! 005 ! N ! ! ! ! 3 ! Plant Code ! 0007 ! 0010 ! 004 ! N ! ! ! ! 4 ! Generator Code ! 0011 ! 0014 ! 004 ! A ! ! ! ! 5 ! Milestones ! 0015 ! 0254 ! 240 ! N ! ! Note 2 ! ! 6 ! Notes Flag ! 0255 ! 0255 ! 001 ! A ! ! ! ! 7 ! Notes ! 0256 ! 0375 ! 120 ! A ! ! ! ! ! ! ! ! ! ! ! ! ----------------------------------------------------------------------------------------- . A - Alpha/Numeric .. LB - Left Justify, Blank Filled N - Numeric LZ - Left Justify, Zero Filled D - Duplicate RB - Right Justify, Blank Filled S - Skip RZ - Right Justify, Zero Filled Unless otherwise noted all alpha/numeric fields are left justified, blank filled. All numeric fields are right justified, zero filled. Note 1: This field must contain a '5' for this layout to apply. Note 2: The milestone field contains a one dimensional array which occurs 20 times. The logical layout of the 240 columns follows. The numeric values are unpacked decimal. There is a one to one correspondence between the 20 occurrences and the 20 milestones listed on Schedule 5 of Form EIA-860. The format is Common Business Oriented Language (COBOL). 05 MILESTONE OCCURS 20 TIMES. 10 PLANNED-DATE PIC 9(6). 10 ACTUAL-DATE PIC 9(6). The two numeric fields do not contain negative values or decimal points.